Sewerage (Lighting Ventilation and Construction) Regulations 1971



    13A. Walls, etc., in showers

    (1) Any area of a wall in a shower compartment or shower that

    (a) is within a horizontal distance of 915 mm from the shower rose; or

    (b) is directly below any point that is within a horizontal distance of 915 mm from the shower rose,

    shall have an impervious surface.

    (2) A window within a distance of 915 mm of a shower rose shall have

    (a) a fixed glass;

    (b) a sill that is splayed to an angle of 45 degrees from the horizontal; and

    (c) a sill and frame that have an impervious surface.

    [Regulation 13A inserted in Gazette 16 Nov 1973 p. 4222.]



Note: This is not an authorised version. The only authorised version is the hardcopy (printed) version published under authority of the Government Printer, available from the State Law Publisher, 10 William St Perth W.A. 6000.